Mc_Movevelocity; Mc_Movevelocity: Move Axes At Predefined Velocity V2 - Siemens SIMATIC S7-1500 Function Manual

Update 3
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

This error is resolved by resetting the two inputs "Jog_F" and "Jog_B".
During the braking ramp, "Jog_F" is set at time
configured velocity. When the setpoint velocity 100.0 is reached, this is signaled via
"InVel" = TRUE.
11.1.4

MC_MoveVelocity

11.1.4.1

MC_MoveVelocity: Move axes at predefined velocity V2

Description
With the Motion Control instruction "MC_MoveVelocity", you can move an axis with a
constant velocity.
Dynamic behavior during movement is defined with the parameters "Velocity", "Jerk",
"Acceleration" and "Deceleration".
● Positioning axis/synchronous axis:
● Speed axis:
Applies to
● Synchronous axis
● Positioning axis
● Speed axis
Requirement
● The technology object has been configured correctly.
● The technology object is enabled.
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
A velocity is specified in the "Velocity" parameter.
A speed is specified at the "Velocity" parameter.
11.1 S7-1500 Motion Control V2
. The axis is accelerated to the last
Instructions