Tag
DriveParameter.
ReferenceSpeed
MaxSpeed
See also
Evaluating the technology data block (Page 173)
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
A.2 Tags of the positioning axis/synchronous axis technology object
Data type
Values
LREAL
0.0 to 1.0E12
LREAL
0.0 to 1.0E12
W
Description
RES
Reference value (100%) for the setpoint speed of
the drive (N-set)
The setpoint speed is transmitted in the
PROFIdrive frame as a standardized value from -
200% to 200% of the "ReferenceSpeed".
For setpoint specification via an analog output,
the analog output can be operated in the range
from -117% to 117%, insofar as the drive permits
this.
RES
Maximum value for the setpoint speed of the
drive (N-set)
(PROFIdrive: MaxSpeed ≤ 2 × ReferenceSpeed
Analog setpoint: MaxSpeed ≤ 1.17 × Refer-
enceSpeed)
Appendix
335