Appendix
A.4 Technology alarms
A.4
Technology alarms
A.4.1
Overview
The following table shows an overview of the technology alarms and the corresponding
alarm reactions. When a technology alarm occurs, evaluate the entire indicated alarm text, in
order to find the precise cause.
Legend
No.
Response
Error bit
Warning bit
Restart
Alarm text
List of the technology alarms
No.
Response
101 Remove enable
104 Stop with maximum
dynamic values
105 Remove enable
106 Remove enable
107 Remove enable
108 Remove enable
109 Remove enable
110 No reaction
201 Remove enable
202 No reaction
203 Remove enable
368
Number of the technology alarm
(corresponds to <TO>.ErrorDetail.Number)
Effective alarm reaction
(corresponds to <TO>.ErrorDetail.Reaction)
Bit that is set in <TO>.ErrorWord when the technology alarm occurs
Bit that is set in <TO>.WarningWord when the technology alarm occurs
To acknowledge the technology alarm, the technology object must be reinitialized
(restart).
Indicated alarm test (limited)
Error bit
Warning bit
X1 (Configuration-
-
Fault)
X1 (Configuration-
-
Fault)
X1 (Configuration-
-
Fault)
X1 (Configuration-
-
Fault)
X1 (Configuration-
-
Fault)
X1 (Configuration-
-
Fault)
X1 (Configuration-
-
Fault)
-
X1
(Configuration-
Fault)
X0 (SystemFault)
-
X0 (SystemFault)
-
X0 (SystemFault)
-
Restart
X
Error in the configuration.
-
Error in the specification of software limit
switches.
X
Configuration mode (drive/actuator).
X
Configuration error in the drive actuator
driver.
X
Configuration error encoder.
X
Configuration error encoder driver.
-
Configuration error.
-
Configuration is being internally adapted.
-
Internal error.
-
Internal configuration error.
-
Internal error. Please contact customer
service.
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
Alarm text