Appendix
A.2 Tags of the positioning axis/synchronous axis technology object
Tag
Data type
Bit 8
-
Bit 9
-
Bit 10
-
Bit 11
-
Bit 12
-
Bit 13
-
Bit 14
-
Bit 15...
-
Bit 31
See also
Evaluating the technology data block (Page 173)
354
Values
W
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Description
"SWLimit"
Software limit switch reached or overshot.
"HWLimit"
Hardware limit switch reached or overshot.
"HomingFault"
Error during homing process
The homing cannot be completed.
"FollowingErrorFault"
Following error limits exceeded
"PositioningFault"
Positioning error
"PeripheralError"
Error accessing a logical address
Positioning axis technology object:
Reserved
Synchronous axis technology object:
"SynchronousError"
Error during synchronous operation
The leading axis specified at the Motion Control instruction "MC_GearIn"
was not configured as a possible leading axis.
Reserved
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC