A.4.2

Technology alarms 101-110

Technology alarm 101
Alarm reaction: Remove enable
Restart: required
Alarm text
Error in the configuration
Faulty load gear factors.
Illegal value for the configuration data Actor.DriveParameter.MaxSpeed.
Illegal value for the configuration data DynamicLimits.MaxVelocity.
Illegal value for the configuration data maximum acceleration in Dynam-
icLimits.MaxAcceleration.
The set leadscrew pitch is invalid. Illegal value in Mechanics.Leadscrew
Illegal combination of data for homing with incremental encoder.
The set mounting position of the encoder is invalid. Illegal value in Sen-
sor.MountingMode.
The configuration of the measuring wheel circumference of the encoder is invalid.
Illegal value in Sensor.Parameter.DistancePerRevolution.
The configuration for the resolution of the linear encoder is faulty. Illegal value in
Sensor.Parameter.Resolution.
The set resolution of the encoder is invalid. Illegal value in Sen-
sor.Parameter.StepsPerRevolution.
The set fine resolution for Gn_XIST1 is invalid. Illegal value in Sen-
sor.Parameter.FineResolutionXist1.
The set fine resolution for Gn_XIST1 in Sensor.Parameter.FineResolutionXist1 is not
consistent with the setting in PROFIdrive parameter P979.
Illegal value for the configuration data Actor.Interface.Telegram.
The set encoder type is invalid. Illegal value in Sensor.Type.
The set encoder system is invalid. Invalid value in Sensor.System.
The set home position offset is invalid. Illegal value in Sen-
sor.ActiveHoming.HomePositionOffset.
Parameter of position monitoring faulty. Illegal value in PositioningMonitoring.Window. Adjust the specified value.
Parameter of position monitoring faulty. Illegal value in PositioningMonitoring.Window. Adjust the specified value.
The set home position offset is invalid. Illegal value in Sensor.ActiveHoming.Mode.
The set home position offset is invalid. Illegal value in Sensor.PassiveHoming.Mode.
The configuration of the PROFIdrive interface of the actual value is faulty. Illegal
value in Sensor.Interface.Telegram.
Faulty controller factors.
Limit for standstill signal is faulty. Illegal value in StandStillSignal.VelocityThreshold.
Parameter of position monitoring faulty. Invalid value in PositioningMonitor-
ing.ToleranceTime.
Illegal value in Actor.Type.
Inconsistent PROFIBUS parameterization; the sum of Ti and To is greater than one
DP cycle clock.
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
Appendix
A.4 Technology alarms
Solution
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
Adjust the specified value.
371