Statussensor Tags (External Encoder) - Siemens SIMATIC S7-1500 Function Manual

Update 3
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

A.3.9

StatusSensor tags (external encoder)

The tag structure <TO>.StatusSensor.<tag name> indicates the status of the measuring
system.
Tags
Legend (Page 358)
Tag
StatusSensor.
State
CommunicationOK
Error
AbsEncoderOffset
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
Data type
Values
STRUCT
DINT
-
BOOL
-
BOOL
-
LREAL
-
A.3 Tags of the technology object external encoder
W
Description
RON
Status of the actual encoder value:
0: "NOT_VALID (not valid)
1: "Waiting_FOR_VALID (waiting for valid status)
2: "VALID (valid)
RON
Cyclic BUS communication between controller and
encoder
FALSE: Not established
TRUE: Established
RON
FALSE: No error in the measuring system
TRUE: Error in the measuring system.
RON
Home point offset to the value of an absolute value
encoder. The value will be retentively stored in the
CPU.
Appendix
363