Bit 5—Input Capture/Compare Match Interrupt Enable A1 (IMIEA1): Enables or disables
the interrupt requested by the IMFA1 flag when IMFA1 is set to 1.
Bit 5
IMIEA1
Description
0
IMIA1 interrupt requested by IMFA1 flag is disabled
1
IMIA1 interrupt requested by IMFA1 flag is enabled
Bit 4—Input Capture/Compare Match Interrupt Enable A0 (IMIEA0): Enables or disables
the interrupt requested by the IMFA0 flag when IMFA0 is set to 1.
Bit 4
IMIEA0
Description
0
IMIA0 interrupt requested by IMFA0 flag is disabled
1
IMIA0 interrupt requested by IMFA0 flag is enabled
Bit 3—Reserved: This bit cannot be modified and is always read as 1.
Bit 2—Input Capture/Compare Match Flag A2 (IMFA2): This status flag indicates GRA2
compare match or input capture events.
Bit 2
IMFA2
Description
0
[Clearing condition]
Read IMFA2 flag when IMFA2 =1, then write 0 in IMFA2 flag
1
[Setting conditions]
16TCNT2 = GRA2 when GRA2 functions as an output compare register
16TCNT2 value is transferred to GRA2 by an input capture signal when GRA2
functions as an input capture register