Example of Non-Overlapping TPC Output (Example of Four-Phase Complementary Non-
Overlapping Output): Figure 10.7 shows an example of the use of TPC output for four-phase
complementary non-overlapping pulse output.
TCNT value
GRB
TCNT
GRA
H'0000
NDRB
95
PBDR
00
TP
15
TP
14
TP
13
TP
12
TP
11
TP
10
TP
9
TP
8
1.
The 16-bit timer channel to be used as the output trigger channel is set up so that GRA and GRB are
output compare registers and the counter will be cleared by compare match B. The TPC output trigger
period is set in GRB. The non-overlap margin is set in GRA. The IMIEA bit is set to 1 in TISRA to enable
IMFA interrupts.
2.
H'FF is written in PBDDR and NDERB, and bits G3CMS1, G3CMS0, G2CMS1, and G2CMS0 are set in
TPCR to select compare match in the 16-bit timer channel set up in step 1 as the output trigger. Bits
G3NOV and G2NOV are set to 1 in TPMR to select non-overlapping output. Output data H'95 is written in
NDRB.
3.
The timer counter in this 16-bit timer channel is started. When compare match B occurs, outputs change
from 1 to 0. When compare match A occurs, outputs change from 0 to 1 (the change from 0 to 1 is delayed
by the value of GRA). The IMFA interrupt service routine writes the next output data (H'65) in NDRB.
4.
Four-phase complementary non-overlapping pulse output can be obtained by writing H'59, H'56, H'95...
at successive IMFA interrupts.
Figure 10.7 Non-Overlapping TPC Output Example (Four-Phase Complementary
294
65
59
95
05
65
41
Non-overlap margin
Non-Overlapping Pulse Output)
56
95
59
50
56
14
65
95
05
65
Time

Advertisement

Table of Contents
loading

Table of Contents