DB31, ...
DBX101.6
Signal state 0 or edge
change 1 → 0
Corresponding to ....
DB31, ...
DBX101.7
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
Corresponding to ....
2.3

Cycle Times (G3)

No signal descriptions required.
2.4

Contour Tunnel Monitoring (K6)

No signal descriptions required.
Special functions: NC/PLC interface signals (Z3)
Function Manual, 11/2006, 6FC5397-2BP10-2BA0
Gantry leading axis
The axis is defined as the synchronized axis within a gantry axis grouping (see MD37100).
It is not possible to traverse a synchronized axis directly by hand (in JOG mode) or to
program it in a part program.
Note:
The following interface signals are output to the PLC via the PLC interface of the gantry
synchronized axis:
DB31, ...DBX101.3 (gantry warning limit exceeded)
DB31, ...DBX101.2 (gantry trip limit exceeded)
The NCK does not evaluate individual axial PLC interface signals for the synchronized axis.
MD37100 $MA_GANTRY_AXIS_TYPE (gantry axis definition)
DB31, ...DBX101.7 (gantry axis)
Gantry axis
The axis is defined as a gantry axis within a gantry axis grouping (see MD37100).
The PLC user program can read IS "Gantry leading axis" to detect whether the axis has been
declared as a leading or synchronized axis.
The axis is not defined as a gantry axis (see MD37100).
MD37100 $MA_GANTRY_AXIS_TYPE (gantry axis definition)
DB31, ... DBX101.6 (gantry leading axis)
Signal(s) updated: Cyclic
Detailed description