Detailed description

2.2 Start-up

Behavior with single block and G60
Due to the internal motion logic, negative offset distances (lead) have no effect when used
with the following standard functions:
• Single block
• Exact stop at block end (G60)
Note
Negative offset distances (lead) have no effect when used with the "single block" and "exact
stop at block end (G60)" standard functions.
Behavior in the event of an interruption in the part program
Following an interruption in the part program (NC-STOP) and subsequent change to JOG
mode, the technological function is deactivated and/or switching signals cease to be output.
The technological function is only restarted and/or switching signals output once the system
has reverted to AUTOMATIC mode and the part program has been resumed (NC START).
2.2
Start-up
Compile cycle
Before starting up the technological function, make sure that the corresponding compile
cycle has been loaded and activated.
(840D)
References:
/FB3/ Function Manual for Special Functions, Installation of Compile Cycles (TE0)
(840Di)
References:
/HBi/ SINUMERIK 840Di Manual, NC Start-up with HMI Advanced, Loadable Compile Cycles
10
Special functions: Cycle-Independent Path-Synchronous Signal Output (TE8)
Function Manual, 11/2006, 6FC5397-2BP10-2BA0