2.2 Gantry Axes (G1)
DB31, ...
DBX29.5
Application example(s)
2.2.2

Signals from axis/spindle (DB31, ...)

DB31, ...
DBX101.2
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
Signal state 0 or edge
change 1 → 0
Signal irrelevant for ...
Corresponding to ....
DB31, ...
DBX101.3
Edge evaluation: No
Signal state 1 or edge
change 0 → 1
10
Automatic synchronization
The automatic synchronization process can be disabled by sending a VDI signal to the axial
PLC → NC interface of the master axis. This always makes sense when the axes are not
activated by default. In this case, the synchronization process should also be started
explicitly.
Gantry trip limit exceeded
The difference between the position actual values of the leading and synchronized axes has
exceeded the maximum permissible limit value. The axes in the gantry grouping are shut
down internally in the control. Alarm 10653 "Error limit exceeded" is also output.
The monitored limit value is derived from the following machine data:
MD37120 $MA_GANTRY_POS_TOL_ERROR (gantry trip limit)
... if gantry grouping is synchronized.
MD37130 $MA_GANTRY_POS_TOL_REF (gantry trip limit for referencing)
... if gantry grouping is not yet synchronized.
Note:
IS "Gantry trip limit exceeded" is output to the PLC via the PLC interface of the synchronized
axis.
The difference between the position actual values of the leading and synchronized axes is
still within the permissible tolerance range.
Gantry leading axis
MD37120 $MA_GANTRY_POS_TOL_ERROR (gantry trip limit)
MD37130 $MA_GANTRY_POS_TOL_REF (gantry trip limit for referencing)
DB31, ... DBX101.5 (gantry grouping is synchronized)
Gantry warning limit exceeded
The difference between the position actual values of the leading and synchronized axes has
exceeded the limit value defined by the following machine data:
MD37110 $MA_GANTRY_POS_TOL_WARNING (gantry warning limit)
The message "Warning limit exceeded" is also output.
Note:
IS "Gantry warning limit exceeded" is output to the PLC via the PLC interface of the
synchronized axis.