7. Rename the file to "slaesvcadapconf.xml".
8. Open the "slaesvcadapconf.xml" file in the editor and record the new base name
9. Restart HMI sl.
Further information about creating alarm text files with HMI sl can be taken from:
Literature:
/IAM/ SINUMERIK 840D sl Commissioning Manual; Chapter: Configuring user alarm texts
2.1.8.2
Creating alarm texts with HMI Advanced
The following alarms should be added to the alarm texts of the technology functions:
075999 0 0 "Channel %1 Sentence %2 Call parameter is invalid"
Proceed as follows
1. Copy the "mbdde.ini" file from the "F:\mmc2" directory to the "F:\oem" directory.
2. Add the following two lines in the "mbdde.ini" file:
3. Create the language-dependent "alc_XX.com" text files in the "F:\oem" directory, e.g.:
4. Insert the new alarm text in the language-dependent text files, e.g.:
5. Restart HMI Advanced.
For more information about creating alarm texts with HMI Advanced, please refer to:
Literature:
/IAM/ SINUMERIK 840D sl/840Di sl/840D/840Di/810D Startup CNC Part 2 (HMI); Startup
HMI Advanced (IM4), Chapter: Creating user alarm texts
Note
HMI reinstallation
Retain the added alarm texts in the text files of the F:\oem even after a reinstallation of HMI.
Special functions: Installation and Activation of Loadable Compile Cycles (TE01)
Function Manual, 11/2006, 6FC5397-2BP10-2BA0
(filename of the newly created alarm text file without language code and postfix), e.g.:
<BaseNames>
<BaseName_02 type="QString" value="xxx"/>
</BaseNames>
[TextFiles]
UserCZYK=F:\oem\alc_
"alc_GR.com" for German
"alc_UK.com" for English
075999 0 0 "Channel %1 Sentence %2 Call parameter is invalid"
in the text file in German.
2.1 Loadable compile cycles 840D/840D sl