2.5.3.2
Switch off coupling module (CPOF)
An activated coupling can be deactivated with the CPOF switching command. The
deactivation, i.e. the switching off of the coupling to the leading axis, is performed in
accordance with the set switch-off properties (see CPFMOF)
Programming
Syntax:
Identifiers:
Functionality:
Following axis/
spindle:
Example:
CPOF=(X2)
Boundary conditions
• The switch command CPOF results in a preprocessing stop with active coupling.
• A CPOF switching command on an already deactivated or deleted coupling module has
• CPOF can be programmed in synchronous actions.
Special functions: Axis Couplings and ESR (M3)
Function Manual, 11/2006, 6FC5397-2BP10-2BA0
CPOF= (<Following axis / spindle>)
Coupling Off
Deactivate the coupling of the following axis to all defined leading axes.
Type: AXIS
Range of
values:
Exception: CPSETTYPE="COUP" does not result in a preprocessing stop
no effect and is not executed.
All defined axis and spindle identifiers in the channel
; Deactivation of coupling of following axis X2.
Detailed description
2.5 Generic coupling
91