Siemens sinumerik 840D sl Function Manual page 527

Hide thumbs Also See for sinumerik 840D sl:
Table of Contents

Advertisement

Detailed description
2.5 Startup
2.5.4
Parameter settings for input signals (840Di)
The following input signals must be parameterized in the machine data:
• Clearance sensor input voltage
• "Sensor collision" input signal (optional)
Analog input
The following machine data must be parameterized for the analog input:
• MD10300 $MN_FASTIO_ANA_NUM_INPUTS (number of active analog NCK inputs)
• MD10362 $MN_HW_ASSIGN_ANA_FASTIN (hardware inputs for the fast analog NCK
Digital input
Subsequent parameter settings do not have to be made if a digital input on the MCI board
extension module (option) is used.
If an I/O module on PROFIBUS-DP is used for the digital input, the following machine data
must be parameterized:
• MD10350 $MN_FASTIO_DIG_NUM_INPUTS (number of active digital NCK input bytes)
• MD10366 $MN_HW_ASSIGN_DIG_FASTIN (hardware assignment for the external digital
A complete description of the parameter settings for analog and digital I/Os on a
SINUMERIK 840Di appears in:
References:
/HBi/ SINUMERIK 840Di Manual, NC Installation and Start-Up with HMI Advanced, Digital
and Analog I/Os chapter
A complete description of the analog and digital inputs appears in:
References:
/FB2/ Function Manual, Extended Functions, Digital and Analog NCK I/Os (A4)
22
– 1 analog input
– 1 digital input
inputs)
I/O address of the I/O module
NCK inputs)
I/O address of the I/O module
Special functions: Clearance Control (TE1)
Function Manual, 11/2006, 6FC5397-2BP10-2BA0