HMI Advanced
Proceed as follows to create and display the GUD variables in HMI Advanced.
1. Setting the password
2. Activate the "definitions" display.
3. If no SGUD.DEF file is yet available:
• Name: SGUD
• Type: Global data/system
1. Edit the GUD variable definitions
2. Save the file and close the editor.
3. Activate the SGUD.DEF file.
The GUD variables for clearance control are now displayed under:
Operating area switchover > Parameters > User data > Channel user data
HMI Embedded
Proceed as follows to create and display the GUD variables in HMI Embedded.
1. Setting the password
2. If no SGUD.DEF file is yet available:
• Name: SGUD
• Type: DEF
1. Edit the GUD variable definitions
2. Save the file and close the editor.
Special functions: Clearance Control (TE1)
Function Manual, 11/2006, 6FC5397-2BP10-2BA0
Enter the password for protection level 1: (machine manufacturer).
Operating area switchover > Services > Data Selection
Operating area switchover > Services > Data admin > New...
Confirm with OK.
This opens the file in the editor.
DEF CHAN REAL CLC_DISTANCE[3] ; Array of real, 3 elements
DEF CHAN REAL CLC_VOLTAGE[3] ; Array of real, 3 elements
M30
Enter the password for protection level 1: (machine manufacturer).
Operating area switchover > Services > Data admin > Programs/Data: Set cursor to
definitions > New...
Confirm with OK.
This opens the file in the editor.
DEF CHAN REAL CLC_DISTANCE[3] ; Array of real, 3 elements
DEF CHAN REAL CLC_VOLTAGE[3] ; Array of real, 3 elements
M30
Detailed description
2.7 Function -specific display data