2.2.3
Commissioning
2.2.3.1
Memory configuration
A defined storage space is available for the curve tables in the static and dynamic NC
memory, which is defined through the following machine data:
Static NC memory
MD18400 $MN_MM_NUM_CURVE_TABS
MD18402 $MN_MM_NUM_CURVE_SEGMENTS
MD18403 $MN_MM_NUM_CURVE_SEG_LIN
MD18404 $MN_MM_NUM_CURVE_POLYNOMS
Dynamic NC memory
MD18406 $MN_MM_NUM_CURVE_TABS_DRAM
MD18408 $MN_MM_NUM_CURVE_SEGNENTS_DRAM
MD18409 $MN_MM_NUM_CURVE_SEG_LIN_DRAM
MD18410 $MN_MM_NUM_CURVE_POLYNOMS_DRAM
Note
A curve table with linear segments can be stored efficiently in the memory only if:
MD18403 > 0 or MD18409 > 0
If no memory areas are created with this machine data, then the linear segments are stored
as polynomial segments.
Special functions: Axis Couplings and ESR (M3)
Function Manual, 11/2006, 6FC5397-2BP10-2BA0
Defines the number of curve tables that can be stored in the
static NC memory.
Defines the number of curve table segments that can be
stored in the static NC memory.
Defines the maximum number of linear segments in the static
NC memory.
Defines the number of curve table polynomes that can be
stored in the static NC memory.
Defines the number of curve tables that can be stored in the
dynamic NC memory.
Defines the number of curve table segments that can be
stored in the dynamic NC memory.
Defines the maximum number of linear segments in the
dynamic NC memory.
Defines the number of curve table polynomes that can be
stored in the dynamic NC memory.
Detailed description