Ricoh MP C2504 Field Service Manual page 1391

Hide thumbs Also See for MP C2504:
Table of Contents

Advertisement

3. Engine SP Mode Tables
1-955-013 Ozone Fan Low Speed Op
1-955-014 Ozone Fan Middle Speed Op
1-955-015 Ozone Fan High Speed Op
1-955-016 Paper Exit Cooling Fan Op
1-955-017 PSU Cooling Fan Op Start Time
1-955-018 Fan Op Sw Temp Thers
1-955-019 Paper Exit Cooling Fan Control
1-955-020 PSU Cooling Fan Control Off
1-955-051 Dev Suction Fan: Right Op Sw
1-955-062 Dev Suction Fan: Right Op Start
1-955-063 Paper Exit Cooling Fan Op
1-955-064 PSU Cooling Fan Op Start Time
1-955-065 PSU Cooling Fan Op Start Time
1-955-066 PSU Cooling Fan Op Start Time
1-955-071 Ozone Fan Extra Op DUTY
156
DUTY
DUTY
DUTY
Start Time A
A
Off Mode Time
Mode Time
Temp
Time
Start Time B
B
C
D
*ENG
[0 to 100 / 30 / 1%/step]
*ENG
[0 to 100 / 40 / 1%/step]
*ENG
[0 to 100 / 40 / 1%/step]
*ENG
[0 to 900 / 300 / 1sec/step]
*ENG
[0 to 900 / 300 / 1sec/step]
*ENG
[0 to 100 / 2 / 0.1deg/step]
*ENG
[0 to 3600 / 600 / 1sec/step]
*ENG
[0 to 3600 / 600 / 1sec/step]
*ENG
[0 to 100 / 36 / 0.1deg/step]
*ENG
[0 to 900 / 300 / 1sec/step]
*ENG
[0 to 900 / 300 / 1sec/step]
*ENG
[0 to 900 / 300 / 1sec/step]
*ENG
[0 to 900 / * / 1sec/step]
*NA: 300, EU: 120, Asia: 120, CHN:
120, TWN: 300, KOR: 120
*ENG
[0 to 900 / * / 1sec/step]
*NA: 300, EU: 120, Asia: 120, CHN:
120, TWN: 300, KOR: 120
*ENG
[0 to 100 / 20 / 1%/step]