Service cases - hardware
4.5 Machine control panels
4.5.3

Status display MCP interface PN

LEDs for status display
For the MCP interface PN, the following LEDs provide information about the module status:
Figure 4-8
Meaning of the LED
Power OFF
Power ON (voltage is stable)
Boot software runs and the system software
is loaded
The system software is booting
The system software is running, no commu‐
nication to the controller
STOP state: The system software is run‐
ning, communication to the controller
RUN state: The system software is running,
communication to the controller
Overtemperature alarm
4.5.4

This is how you remove the MCP interface PN

Removing
If the module has a hardware defect, then it must be replaced by an identical part.
Precondition: The control cabinet is in a no-voltage condition, all of the connectors and cables
are labeled.
96
Status display
H500
H501
(green)
(green)
PowerOK
PN Sync
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
OFF
ON
ON
ON
Flashes at
0.5 Hz
--
--
Service Manual, 08/2018, 6FC5397-5DP40-6BA1
H502 (red)
H505 (red)
PN fault
OVTemp
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
--
ON
Software and hardware