Identifying Faulty Dimms; Determine Which Dimm Is Faulty (Oracle Ilom); Determine Which Dimm Is Faulty (Psh) - Oracle SPARC T8-4 Service Manual

Hide thumbs Also See for SPARC T8-4:
Table of Contents

Advertisement

Identifying Faulty DIMMs

"Understanding DIMM Configurations" on page 69
"Identifying DIMMs" on page 71
"DIMM Configuration Errors" on page 72
Identifying Faulty DIMMs
You can identify faulty DIMMs using the following methods:
"Determine Which DIMM Is Faulty (Oracle ILOM)" on page 74
"Determine Which DIMM Is Faulty (PSH)" on page 74
"Determine Which DIMM Is Faulty (DIMM Fault LEDs)" on page 76

Determine Which DIMM Is Faulty (Oracle ILOM)

If you suspect that the server has a memory problem, run the Oracle ILOM show
faulty command.
This command lists memory faults and identifies the DIMM modules associated with the fault.
Related Information
"Determine Which DIMM Is Faulty (PSH)" on page 74
"Determine Which DIMM Is Faulty (DIMM Fault LEDs)" on page 76

Determine Which DIMM Is Faulty (PSH)

The Oracle Fault Management tool fmadm faulty displays current server faults, including
DIMM failures.
Start the Fault Management Shell:
1.
-> start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y
2.
Type:
faultmgmtsp> fmadm faulty
------------------- ------------------------------------ -------------- ------
Time
UUID
74
SPARC T8-4 Server Service Manual • January 2022
msgid
Severity

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPARC T8-4 and is the answer not in the manual?

Questions and answers

Table of Contents