set at the Place position..
a. To manually set the Place Actuator to
the correct nozzle height, press Place
Extend
b. Use a 2.5mm hex wrench to hold the
Actuator Adjustment Screw in place
from the bottom, while loosening the
Jam Nut on top of the Actuator
Adjustment Screw with an 8mm open
ended wrench. Lower the Nozzle until
the part is barely touching the top of
the pocket in the Place Location.
c. Tighten the Jam Nut.
d. Press Place Retract to retract the Nozzle to a safe height.
e. Press the right Arrow Key to move to the next Job Wizard screen.