Safe Maintenance Steps

Caution! It is dangerous to service or maintain the TM-401 while it is con-
nected to air and power supplies.
Before performing any maintenance tasks, ensure the machine is stationary and
disconnect the electrical and pneumatic power supplies placing the unplugged
cables in clear view. Follow your company's Lock-out/Tag-out Procedures.
Follow the steps below when performing routine maintenance or cleaning the TM-401.
1.
Turn the TM-401 OFF.
2.
Ensure the Main Power Switch is rotated to the OFF position. The
Main Power Switch is Lock-out/Tag-out capable. Follow your com-
pany's Lock-out/Tag-out procedure to ensure safe maintenance.
3.
Ensure the Air Regulator is rotated to the OFF position.
The Air Regulator is Lock-out/Tag-out capable. Follow
your company's Lock-out/Tag-out procedure to ensure
safe maintenance.
4.
Disconnect the air supply and place the unplugged air
hose so it is clearly visible.
5.
Disconnect the power supply and place the unplugged
power cord so it is clearly visible.
6.
Remove all carrier and cover tape from the Taper.
7.
Remove parts from the Tube Feeder.
8.
Perform cleaning/maintenance as needed.
9.
Reload Tube Feeder parts.
10. Reload Taper carrier tape and cover tape.
11. Reconnect the air supply.
12. Reconnect the power supply.
13. Turn the TM-401 back ON.