Chapter 4: Setup

Test Seal

Step 7:
Seal Test
Perform a Seal Test to ensure a good seal. Adjust Sealer settings in the HMI Taper tab as
necessary.
1.
Run the tape through the taping module by pressing the Continuous Advance
button in the HMI Taper Tab.
2.
As the seal is occurring, watch the alignment of the cover tape with the carrier
tape. The cover tape should run exactly in the groove of the cover tape guide and
the seal should appear as a solid, consistent line. If the seal width is incorrect, stop
the Taper by pressing the Continuous Advance button again.
3.
Adjust the seal positions as necessary. The sealer's inside and outside seals are
independently adjustable. If one of the seals needs to be moved, loosen the
corresponding position lock and turn the adjusters.
D292104.7a.fm
Position Lock
Outer Seal Adjust
Inner Seal Adjust
Position Lock
4- 27

Test Seal