The third Taper Setup screen focuses on Sealer Settings. It will vary in appearance depending on
the type of sealer selected. In the example below, the selected Seal Type is Heat.
Taper Screen 3
A.
The Seal Type button toggles between Heat seal and PSA seal.
The Dwell Time field is only active when heat seal is ON. Dwell time refers to the
amount of time that the Heat Seal Shoes are in contact with the Cover Tape.
Enter the desired dwell time in milliseconds in this field.
The Manual Seal button activates the sealer to perform one seal.
B.
The Set Point field allows the user to select the Heat Sealer set point, or target
temperature. Press the field to open the keypad, then enter the desired tempera-
ture in degrees Celsius.
The Measured field shows the current Heat Sealer temperature in degrees Cel-
sius.
Note: The TM-401 accommodates a wide range of carrier tapes and cover tapes. Set-
tings may vary from one tape product to another. The recommended starting point is 90°
C. The maximum recommended operating temperature is 160°
each seal shoe should be increased or decreased as needed after running a peel force
test.