6-6

Setup the Manual Tube Input Device (MTID)

Step 3:
Setup
1.
Ensure the correct tooling is installed.
MTID
2.
Adjust Feeder position on Sliding Plate so nozzle is centered over pick position..
3.
Load filled tubes into feeder..
Note: The TM-401 is designed to work with
one or two MTIDs installed. Follow the
setup procedures for both MTIDs if the
optional second feeder is installed.
4.
Turn the Vibratory ON and set Vibratory
Off Delay.
5.
Adjust the Vibratory's Amplitude and
Frequency controls as needed to feed
selected parts smoothly.
Preparing to Run a Pre-programmed Job
Adjust feeder position on Slotted Plate
Y Axis Clamping Bolts