3.
Press the Right Arrow to move to the next Head Tab..
Jog the head up or down until the nozzle is centered correctly over the place location.
When the nozzle is positioned correctly, press the Set Place Position button.
4.
Adjust Place Position Z. Manually adjust the right Actuator Adjustment Screw up or
down until the nozzle is extended the appropriate distance above the place location. You
may need to experiment with placing a part to determine what Z Axis height works best.
When the nozzle is positioned correctly, press the Set Place Position button.
Tips on Part Placement
TM-401 User's Guide
Actuator
Adjustment
Screw