Installing Nozzle & Nozzle Tip
Step 4:
Nozzle
1.
Move the Pick & Place Head to the Place position
Installation
so it is easily accessible from the front. .
SELECT
NOZZLE
2.
Remove the air line from the Nozzle Shank, sup-
porting the Nozzle with one hand while gently pull-
ing the tube off the Nozzle Barb.
3.
Using a 2mm Hex wrench, loosen the set screw
that retains the Nozzle Shaft.
4. Slide the Nozzle Shank down and remove it from
the Pick & Place Assembly. Store the unused
Nozzle Shank and Nozzle Cup in the Spare Parts
Kit.
5. Select the correct Nozzle Shank and Nozzle Cup
for the part that will be run. Press the Nozzle Cup
onto the Nozzle Shaft.
6. Insert the Nozzle Shank into the Actuator Shaft in
the Pick & Place Assembly.
7.
Using a 2mm Hex wrench, tighten the set screw to
retain the Nozzle Shaft..
8.
Re-attach the air line to the Nozzle Barb.
Nozzle Installation
Note: When positioning the Nozzle Shank,
push it all the way up to the Actuator Shaft,
then pull it back slightly (about 1mm) so the
body of the Nozzle Shank doesn't rub the body
of the Actuator.