Chapter 3: Human Machine Interface
B.
If no rotation is required for part placement, skip this step. If part rotation is
required for placement, press Rotate Part to rotate the Nozzle 90°. Follow the
directions in Chapter 4: Setup for manually adjusting the Solenoid to set Pick
Head Rotation.
Press the right Arrow Key to move to the next Job Wizard screen.
Job Wizard Step 10
A.
The Arrow keys allow the user to jog the Pick Head and Carrier Tape forward or
backward in small preset increments. This is useful for centering the Nozzle in the
pick and place positions.
• The Up/Down Arrow keys move the Pick Head forward and backward.
• The Left/Right Arrow keys move the tape left and right in the Taper Track.
B.
Enter the value in millimeters for the Head Jog Step and Taper Jog Step fields.
C.
Pressing Set Place Position saves the current Nozzle position as the Place posi-
tion for the current job. The Learned Position will update to match the Current
Position on the screen.