8-4
General Maintenance Tasks
Daily cleaning
Vacuum or brush off the machine with a stiff bristled paint brush daily, removing dust and debris
from all operating areas including the sensors.

Air Pressure Regulator

Check the incoming air pressure every 40-80
hours of operation to ensure it is set to 85 psi
with all vacuums ON. Adjust if necessary.
Inspect the air regulator for moisture accumula-
tion after every 40 hours of operation. Turn the
petcock on the bottom of the regulator clockwise
to release the fluid if moisture is present. Tighten
the petcock when moisture is gone.
Note: Frequency of moisture build-up will
vary with air quality. Check the Air Pres-
sure Regulator periodically to determine
if fluids need to be released more fre-
quently.
Other than the release of moisture build-up, the TM-401 pneumatic system should not
require adjustment or replacement. Should an issue with the pneumatic system arise, call
V-Tek Service for assistance.
Caution!
The TM-401 air supply should be adjusted to operate at a maximum working
pressure not exceeding 7.6 bar (110 psi). The maximum permissible source
pressure should not exceed 9 bar (130 psi). Failure to set the within these lim-
its could result in a failure in the pneumatic system which could lead to injury.

Lubrication

No lubrication is required or desired on the TM-401 as all parts are no maintenance in this regard
and the use of lubricants could interfere with components.
General Maintenance Tasks
TM-401 User's Guide
Check for moisture here
Petcock
D292104.10a.fm