Misuse
The TM-401 weighs approximately 217 lbs. (98.5 kg.) and requires four people to safely carry it.
Operators are cautioned to follow the instructions and illustrations for safely transporting the TM-
401. Failure to do so could result in injury or damage to the machine.
Lift Points
Installation instructions clearly state that the TM-401 should only be installed or operated on a
level surface to prevent toppling.
The user is protected from moving parts and exposure to objects being ejected under pressure
by 16 standard wire gauge sheet metal and 3/8 inch clear, polycarbonate enclosures. Door sen-
sors ensure operation automatically stops if the enclosure doors are opened. No attempt should
be made to remove these enclosures or to block, disable or override the door sensors.
The enclosure doors may be left open during basic set-up procedures such as positioning the
pick head at place or pick locations. If the enclosure doors are left open during setup the TM-401
automatically reduces the speed of the pick head to a fraction of its normal operating speed to
prevent operator injury due to collision, etc.
The user is protected from the TM-401's heat sealer by a metal guard. Operators are cautioned
not to touch the heat seal guard or to try to reach underneath the guard while the heat sealer is in
operation.
The TM-401 air supply should be adjusted to operate at a maximum working pressure not
exceeding 7.6 bar (110 psi). The maximum permissible source pressure should not exceed 9 bar
(130 psi). Failure to set the air pressure within these limits could result in a failure in the pneu-
matic system which could lead to injury.