7-14
Heat Sealer Inactivity System Alarm
If the Taper is inactive for 40 minutes or longer, the Heat Sealer is automatically disabled. Once
that occurs, if a user attempts to run a job, or use Continuous Advance, Pocket Advance or Man-
ual Seal a Heat Sealer Inactivity system alarm will activate.
When this occurs, tape advance stops, a beep sounds and a warning appears on the HMI.
To clear the Heat Seal Inactivity System Alarm, wait for the heat shoes to reach their set point
and then press CONTINUE to clear the alarm and resume operation. The current temperature is
displayed on the system alarm message.
Note: If the user presses Continue and then attempts to move tape through the sealer
before the temperature has reached the set point, the Temperature Out Of Range system
alarm will appear, prompting the user to wait until the sealer temperature is correct.
System Alarm Messages