Safety Features
Main Power Switch
The Main Power Switch is located on the right side
of the machine. Turning the switch to the right
turns power ON. Turning the switch back to the left
turns the power OFF.
When the Main Switch is in the OFF position, it
exposes a lockout-tagout hole. The switch can be
locked by inserting a lock through the hole. The
switch on the right is pictured in the OFF position.
Emergency Stop Switch
There is one Emergency Stop Switch on the TM-
401. It is located on the left side of the machine
below the Take-up Arm. When an emergency stop
switch is triggered, all motion will be halted and the
machine will require a reset before operation can
continue.
The emergency stop control circuit removes elec-
trical power to all motors, moving parts, heat
sources, pneumatics, and energy storing devices.
This includes the stepper motor drive, stepper
motors, the servo motor drive, servo motors, drive
circuits, the main control board, the heat sealer
and all pneumatics. The only devices that remain
powered are the inspection module cameras, the
enclosure lights, the sensors, and the HMI.
Reset Button
The TM-401's blue Reset button is located on the left side of the machine above the Emergency
Stop Switch. When the machine is powered up, it is automatically placed into an emergency stop
state to prevent the motors from moving until the operator is ready to begin operating the
machine. The error state is cleared by pressing the Reset button on the front of the machine.