YASKAWA L1000A Technical Manual page 73

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

NOTICE: Insulate shields with tape or shrink tubing to prevent contact with other signal lines and equipment. Improper wiring practices
could result in drive or equipment malfunction due to short circuit.
Wire the control circuit only after terminals have been properly grounded and main circuit wiring is complete. Refer to
Figure 3.20
for details. Prepare the ends of the control circuit wiring as shown in
Torque Specifications on page
WARNING! Do not tighten screws beyond the specified tightening torque. Failure to comply may result in erroneous operation, damage
the terminal block, or cause injury due to fire from overheating of loose electrical connections.
NOTICE: Use shielded twisted-pair cables as indicated to prevent operating faults. Improper wiring practices could result in drive or
equipment malfunction due to electrical interference.
Connect control wires as shown in
Figure 3.24
A – Loosen screw to insert wire
B – Single wire or stranded wire
When connecting control wires to the terminals, use shielded twisted-pair wires (treating wire ends as shown in
Figure 3.21
and connect the shield to the ground terminal of the drive.
Figure 3.25
A – Drive side
B – Connect shield to ground terminal of
drive.
C – Insulation
NOTICE: Do not exceed 50 meters (164 ft.) for the control line between the drive and the operator when using an analog signal from a
remote source to supply the frequency reference. Failure to comply could result in poor system performance.
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
71.
Figure
3.20:
A
B
Figure 3.20 Terminal Board Wiring Guide
F
A
B
Figure 3.21 Preparing the Ends of Shielded Cables
Figure
YEA_common
Preparing wire
D
terminal ends
C
C – Avoid fraying wire strands when stripping
insulation from wire. Strip length 5.5 mm.
D – Blade depth of 0.4 mm or less
Blade width of 2.5 mm or less
C
D
E
D – Control device side
E – Shield sheath (insulate with tape or
heat-shrink tubing)
F – Shield
3.8 Control Circuit Wiring
3.21. Refer to
Wire Size and
3
73

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents