4.6 Setup Procedure for Elevator Applications
• When the lightest load direction is up, the drive stops after Light Load Direction Search and then accelerates upwards to
the Rescue Operation speed set in parameter d1-25. The output terminals set for "Light Load Direction" (H2-
and "Light Load Direction detection status"(H2-
Figure 4.31
Light Load Direction Search status
• When the lightest direction is down, then after Light Load Direction Detection is finished the drive immediately
accelerates to the Rescue Operation speed set in d1-25 without stopping. An output terminal set for "Light load
direction" (H2-
= 54) will stay open, and an output terminal set for "Light Load Direction detection status"(H2-
= 55) will close.
Figure 4.32
Light Load Direction Search status
134
H1-
= 55
Off (open)
(Rescue Operation)
Off (open)
Up/Down command
Up command (internal)
Down command (internal)
H2-
= 55
H2-
= 54
Light load direction
Figure 4.35 Light Load Direction Detection (Up)
H1-
= 55
Off (open)
(Rescue Operation)
Off (open)
Up/Down command
Up command (internal)
Down command (internal)
H2-
= 55
H2-
= 54
Light load direction
Figure 4.36 Light Load Direction Detection (Down)
= 55) will close.
On (closed)
On (closed)
Speed agree torque calculations
Up
Down
Off (open)
Off (open)
On (closed)
On (closed)
Speed agree torque calculations
Up
Down
Off (open)
Off (open)
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Up
Elevator moves in the
direction of the light load
On (closed)
On (closed)
Elevator moves in the
direction of the light load
On (closed)
= 54)