E.3 User Setting Table
No.
H3-13
Analog Input Filter Time Constant
H3-16
Offset for Terminal A1
H3-17
Offset for Terminal A2
H4-01
Terminal FM Monitor Selection
H4-02
Terminal FM Gain
H4-03
Terminal FM Bias
H4-04
Terminal AM Monitor Selection
H4-05
Terminal AM Gain
H4-06
Terminal AM Bias
H4-07
Terminal FM Signal Level Selection
H4-08
Terminal AM Signal Level Selection
H5-01
Drive Node Address
H5-02
Communication Speed Selection
H5-03
Communication Parity Selection
H5-04
Stopping Method After Communication Error (CE)
H5-05
Communication Fault Detection Selection
H5-06
Drive Transmit Wait Time
H5-07
RTS Control Selection
H5-09
CE Detection Time
H5-10
Unit Selection for MEMOBUS/Modbus Register 0025H
H5-11
Communications ENTER Function Selection
L1-01
Motor Overload Protection Selection
L1-02
Motor Overload Protection Time
L1-13
Continuous Electrothermal Operation Selection
L2-05
Undervoltage Detection Level (Uv)
L3-01
Stall Prevention Selection during Acceleration
L3-02
Stall Prevention Level during Acceleration
L3-05
Stall Prevention Selection during Run
L3-06
Stall Prevention Level during Run
L4-01
Speed Agreement Detection Level
L4-02
Speed Agreement Detection Width
L4-03
Speed Agreement Detection Level (+/-)
L4-04
Speed Agreement Detection Width (+/-)
L4-05
Speed Reference Loss Detection Selection
L4-06
Speed Reference at Reference Loss
L4-13
Door Zone Level
L5-02
Fault Output Operation during Auto Reset
L5-04
Fault Reset Interval Time
L5-06
Undervoltage Fault Reset Selection
L6-01
Torque Detection Selection 1
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
L6-04
Torque Detection Selection 2
L6-05
Torque Detection Level 2
L6-06
Torque Detection Time 2
L7-01
Forward Torque Limit
L7-02
Reverse Torque Limit
L7-03
Forward Regenerative Torque Limit
L7-04
Reverse Regenerative Torque Limit
L8-02
Overheat Alarm Level
L8-03
Overheat Pre-Alarm Operation Selection
L8-05
Input Phase Loss Protection Selection
L8-06
Input Phase Loss Detection Level
L8-07
Output Phase Loss Protection Selection
L8-09
Output Ground Fault Detection Selection
L8-10
Heatsink Cooling Fan Operation Selection
L8-11
Heatsink Cooling Fan Off Delay Time
L8-12
Ambient Temperature Setting
L8-15
oL2 Characteristics Selection at Low Speeds
L8-27
Overcurrent Detection Gain
436
Name
Setting
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
User
No.
L8-29
Current Unbalance Detection (LF2)
L8-35
Installation Selection
L8-38
Automatic Torque Boost Selection
L8-39
Reduced Carrier Frequency
L8-55
Internal Braking Transistor Protection
L8-62
Operation Selection at Input Phase Loss
L8-77
Oscillation Suppression
L8-88
Safe Disable Operation Mode
n2-01
Speed Feedback Detection Control (AFR) Gain
n2-02
Speed Feedback Detection Control (AFR) Time Constant 1
n2-03
Speed Feedback Detection Control (AFR) Time Constant 2
n5-01
Inertia Compensation Selection
n5-02
Motor Acceleration Time
n5-03
Inertia Compensation Gain
n5-07
Speed Feedback Compensation Selection
n5-08
Speed Feedback Compensation Gain (P)
n6-01
Online Tuning Selection
n6-05
Online Tuning Gain
n8-01
Initial Polarity Estimation Current
n8-02
Pole Attraction Current
n8-29
q-Axis Current Control Gain during Normal Operation
q-Axis Current Control Integral Time during Normal
n8-30
Operation
n8-32
d-Axis Current Control Gain during Normal Operation
d-Axis Current Control Integral Time during Normal
n8-33
Operation
n8-35
Initial Rotor Position Detection Selection
n8-36
High Frequency Injection Level
n8-37
High Frequency Injection Amplitude
n8-62
Output Voltage Limit
n8-81
High Frequency Injection during Rescue Operation
High Frequency Injection Amplitude during Rescue
n8-82
Operation
n8-84
Polarity Detection Current
n8-86
Magnet Pole Search Error Detection Selection
n9-60
A/D Conversion Start Delay
o1-01
Drive Mode Unit Monitor Selection
o1-02
User Monitor Selection After Power Up
o1-03
Digital Operator Display Unit Selection
o1-04
V/f Pattern Setting Units
o1-10
User-Set Display Units Maximum Value
o1-11
User-Set Display Units Decimal Display
o1-12
Length Units
o1-20
Traction Sheave Diameter
o1-21
Roping Ratio
o1-22
Mechanical Gear Ratio
o2-01
LO/RE Key Function Selection
o2-02
STOP Key Function Selection
o2-03
User Parameter Default Value
o2-04
Drive Model Selection
o2-05
Speed Reference Setting Method Selection
o2-06
Operation Selection when Digital Operator is Disconnected
o3-01
Copy Function Selection
o3-02
Copy Allowed Selection
o4-01
Cumulative Operation Time Setting
o4-02
Cumulative Operation Time Selection
o4-03
Cooling Fan Operation Time Setting
o4-05
Capacitor Maintenance Setting
o4-07
DC Bus Pre-charge Relay Maintenance Setting
o4-09
IGBT Maintenance Setting
o4-11
U2, U3 Initialization
Name
Setting
User