YASKAWA L1000A Technical Manual page 187

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

Terminal Status
<1>
Setting
N.O.
N.C.
20
O
21
O
22
O
23
O
24
O
25
O
26
O
27
O
28
O
29
O
2A
O
2B
O
2C
O
2D
O
2E
O
2F
O
<1> Determines the terminal status for each fault, i.e., whether the terminal is normally open or normally closed.
<2> Determines whether detection for each fault should be enabled only during run or always detected.
Setting 50: Nominal speed
Closing a terminal set for "Nominal speed" makes the drive run at the speed reference set to d1-19. Conditions change,
however, according to the speed selection mode set in d1-18. Refer to
page 115
for details.
Setting 51: Intermediate speed
Closing a terminal set for "Intermediate speed" makes the drive run at the speed reference set to d1-20. This setting can
also be used in combination with other input terminals set for 50 (Nominal speed) and 52 (Releveling speed) to switch
between the speed reference set in d1-21 and d1-22. Conditions change, however, according to the speed selection mode
set in d1-18. Refer to
Multi-Speed Inputs 1, 2 (d1-18 = 0 or 3) on page
Setting 52: Releveling speed
Closing a terminal set for "Releveling speed" makes the drive run at the speed reference set to d1-23. Conditions change,
however, according to the speed selection mode set in d1-18. Refer to
page 115
for details.
Setting 53: Leveling speed
Closing a terminal set for "Leveling speed" makes the drive run at the speed reference set to d1-26. Conditions change,
however, according to the speed selection mode set in d1-18. Refer to
page 115
for details.
Setting 54: Inspection operation
Causes the drive to operate at the speed reference set in d1-24. To use Inspection Run, this terminal must be close before
the Up or Down command is entered. Refer to
Setting 55: Rescue operation
Initiates Rescue Operation when the terminal closes. Refer to
Setting 56: Motor contactor feedback
Can be used as monitoring input for the motor contactor and allows the drive to detect contactor malfunction.
Setting 57: High speed limit up
When this input is closed the speed in up direction will be limited to the leveling speed. No speed limit is applied when
the car is going down.
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Detection Conditions
<2>
Detected during
Always Detected
Run only
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
O
Inspection Operation on page 118
Stopping Method
Ramp to Stop
Coast to Stop
(fault)
(fault)
O
O
O
O
O
O
O
O
Multi-Speed Inputs 1, 2 (d1-18 = 0 or 3) on
115. for details
Multi-Speed Inputs 1, 2 (d1-18 = 0 or 3) on
Multi-Speed Inputs 1, 2 (d1-18 = 0 or 3) on
for details.
Rescue Operation on page 123
5.7 H: Terminal Functions
Emergency Stop
Alarm Only
(fault)
(continue running)
O
O
O
O
O
O
O
O
for details.
5
187