S4: Rescue Operation
No. (Addr.)
Name
S4-01
Light Load Direction Search
(6A6H)
Selection
S4-02
Light Load Direction Search
(6A7H)
Method
S4-03
Light Load Direction Search Time
(6A8H)
S4-04
Light Load Direction Search Speed
(6A9H)
Reference
S4-05
Rescue Operation Torque Limit
(6AAH)
S4-06
Rescue Operation Power Supply
(6CCH)
Selection
S4-07
UPS Power
(6CDH)
S4-08
UPS Operation Speed Limit
(6CEH)
Selection
S4-12
DC Bus Voltage during Rescue
(6D2H)
Operation
S4-13
Rescue Operation Power Supply
(6D3H)
Deterioration Detection Level
<5> Default setting is determined by the control mode (A1-02).
S5: Short Floor Operation
No. (Addr.)
Name
S5-01
Short Floor Operation Selection
(6ABH)
S5-02
Nominal Speed for Short Floor
(6ACH)
Calculation
S5-03
Short Floor Minimum Constant
(6ADH)
Speed Time
S5-04
Distance Calculation Acceleration
(6AEH)
Time Gain
S5-05
Distance Calculation Deceleration
(6AFH)
Time Gain
S5-10
Stopping Method Selection
(6B0H)
S5-11
Deceleration Distance
(6B1H)
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Description
All Modes
0: Disabled
1: Enabled
2: Enabled for Motor 1 only
V/f
OLV
Determines how the drive detects the light load direction.
0: Output Current
1: Regenerative direction detection
All Modes
Sets the time to perform Light Load Direction Search.
All Modes
Sets the speed reference to use during Light Load Direction Search.
All Modes
Sets a time limit for Light Load Direction Search.
All Modes
0: Battery
1: UPS (single-phase)
2: UPS (3-phase)
All Modes
Sets the capacity of the UPS.
All Modes
Determines how a speed limit should be applied to the Rescue Operation speed (d1-25) when
operating from a UPS.
0: Disabled
1: Enabled until Light Load Direction Search is complete
2: Enabled until stop
All Modes
Sets the DC bus voltage during Rescue Operation.
All Modes
Determines at which level of backup power supply deterioration a PF5 fault is triggered.
Description
All Modes
0: Disabled
1: Enabled (Short Floor)
2: Enabled (Advance Short Floor)
All Modes
When d1-18 (Speed Priority Selection) is set to 0 or 3, S5-02 determines the rated speed used
during Short Floor.
All Modes
Sets the minimum operation time when the Advanced Short Floor function is enabled (S5-01 =
2).
All Modes
Set for acceleration jerk compensation in Distance Calculation.
All Modes
Set for deceleration jerk compensation in Distance Calculation.
V/f
OLV
0: Disabled
1: Direct Landing
2: Leveling Distance Control
V/f
OLV
Sets the deceleration distance when Stop Distance Control is enabled
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
common_
TMonly
Default: 0
Min: 0
237
Max: 2
common_
TMonly
Default: 1
Min: 0
237
Max: 1
Default: 1.0 s
common_
TMonly
Min: 0.0 s
237
Max: 5.0 s
Default:
common_
<5>
TMonly
Min: 0.00%
237
Max: 20.00%
Default: 100%
common_
TMonly
Min: 0%
238
Max: 300%
common_
TMonly
Default: 0
Min: 0
238
Max: 2
Default: 0.0kVA
common_
TMonly
Min: 0.0kVA
238
Max: 100.0kVA
common_
common_
TMonly
TMonly
Default: 2
Min: 0
238
Max: 2
common_
common_
Default: 0 V
TMonly
TMonly
Min: 0 V
238
Max: 800 V
common_
Default: 80%
TMonly
Min: 10%
238
Max: 100%
Setting
Page
common_
TMonly
Default: 0
Min: 0
241
Max: 2
common_
Default: 0.0%
TMonly
Min: 0.0%
241
Max: 100.0%
common_
Default: 0.0 s
TMonly
Min: 0.0 s
xx
Max: 2.0 s
Default: 150.0%
common_
TMonly
Min: 50.0%
xx
Max: 200.0%
Default: 150.0%
common_
TMonly
Min: 50.0%
xx
Max: 200.0%
common_
TMonly
Default: 0
Min: 0
xx
Max: 2
Default: 0 mm
common_
TMonly
Min: 0 mm
xx
Max: 32767 mm
<36>
B
369