YASKAWA L1000A Technical Manual page 347

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

No.(Addr.)
Name
E2-10
Motor Iron Loss for Torque
(317H)
Compensation
E2-11
Motor Rated Power
(318H)
<4> Default setting value varies by the drive model (o2-04).
<10> The display resolution depends on the rated output power of the drive. Models CIMR-L 2A0018 to 2A0033 and CIMR-L 4A0009 to
4A0018 display values in 0.01 A units, while models CIMR-L 2A0047 to 2A0415 and CIMR-L 4A0024 to 4A0260 display values in 0.1 A
units.
E3: V/f Pattern for Motor 2
These parameters are hidden when a PM motor control mode has been selected for motor 1 (A1-02 = 5, 6, 7).
No.(Addr.)
Name
E3-04
Motor 2 Maximum Output
Frequency
(31AH)
E3-05
Motor 2 Maximum Voltage
(31BH)
E3-06
Motor 2 Base Frequency
(31CH)
E3-07
Motor 2 Mid Output Frequency
(31DH)
E3-08
Motor 2 Mid Output Frequency
(31EH)
Voltage
E3-09
Motor 2 Minimum Output
(31FH)
Frequency
E3-10
Motor 2 Minimum Output
(320H)
Frequency Voltage
<9> Values shown here are for 200 V class drives. The default is 400 V when using a 400 V class drive.
E4: Motor 2 Parameters
These parameters are hidden when a PM motor control mode has been selected for motor 1 (A1-02 = 5, 6, 7).
No.(Addr.)
Name
E4-01
Motor 2 Rated Current
(321H)
E4-02
Motor 2 Rated Slip
(322H)
E4-03
Motor 2 Rated No-Load Current
(323H)
E4-04
Motor 2 Motor Poles
(324H)
E4-05
Motor 2 Line-to-Line Resistance
(325H)
E4-06
Motor 2 Leakage Inductance
(326H)
<4> Default setting value is dependent on the drive model (o2-04)
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Description
V/f
OLV
Sets the motor iron loss.
V/f
OLV
Sets the motor rated power in kilowatts (1 HP = 0.746 kW). Automatically set during
Auto-Tuning.
Description
V/f
OLV
These parameters are only applicable when E1-03 is set to F.
To set linear V/f characteristics, set the same values for E3-07 and E3-09. In this case, the
setting for E3-08 will be disregarded. Ensure that the four frequencies are set according to these
rules or an oPE10 fault will occur:
E3-09 ≤ E3-07 < E3-06 ≤ E3-04
Output Voltage (V)
E3-05
E3-08
E3-10
E3-09
Description
V/f
OLV
Sets the full load current for motor 2. Automatically set during Auto-Tuning.
V/f
OLV
Sets the rated slip for motor 2. Automatically set during Auto-Tuning.
V/f
OLV
Sets the no-load current for motor 2. Automatically set during Auto-Tuning.
V/f
OLV
Sets the number of poles of motor 2. Automatically set during Auto-Tuning.
V/f
OLV
Sets the phase-to-phase resistance for motor 2. Automatically set during Auto-Tuning.
V/f
OLV
Sets the voltage drop for motor 2 due to motor leakage inductance as a percentage of rated
voltage. Automatically set during Auto-Tuning.
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
E3-07
E3-04
Frequency (Hz)
CLV/PM
CLV
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
common_
Default:
<4>
TMonly
Min: 0 W
172
Max: 65535 W
common_
Default:
<4>
TMonly
Min: 0.00 kW
172
Max: 650.00 kW
Setting
Page
Default: 60.0 Hz
Min: 10.0 Hz
173
common_
Max: 120.0 Hz
TMonly
Default: 200.0 V <9>
Min: 0.0 V
173
Max: 255.0 V <9>
Default: 60.0 Hz
Min: 0.0 Hz
173
Max: 120.0 Hz
Default: 3.0 Hz
Min: 0.0 Hz
173
Max: 120.0 Hz
Default: 15.0 V <9>
Min: 0.0 V
173
Max: 255.0 V <9>
Default: 1.5 Hz
Min: 0.0 Hz
173
Max: 120.0 Hz
Default: 9.0 V <9>
Min: 0.0 V
173
Max: 255.0 V <9>
Setting
Page
Default:
>
<4>
Min: 10% of drive rated
common_
current
TMonly
174
Max:
200% of drive rated
current
<10>
common_
Default:
<4>
TMonly
Min: 0.00 Hz
174
Min: 20.00 Hz
common_
Default:
<4>
TMonly
Min: 0 A
174
Min: [E4-01]
<10>
common_
Default: 4
TMonly
Min: 2
174
Max: 48
common_
Default:
<4>
TMonly
Min: 0.000 Ω
175
Max: 65.000 Ω
common_
Default:
<4>
TMonly
Min: 0.0%
175
Max: 40.0%