YASKAWA L1000A Technical Manual page 365

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

No. (Addr.)
Name
o1-22
Mechanical Gear Ratio
(577H)
<5> Default setting is determined by the control mode (A1-02).
<20> This parameter appears when the drive displays user-set units (o1-03 = 3).
<21> The control mode determines the selections available. In V/f Control, only settings 1 through 3 are permitted.
<38> Default setting and setting range changes when inches are selected for the length units (o1-12 = 1). The setting range becomes 3.70 to 78.00
inches, and the default becomes 15.70 inches.
o2: Digital Operator Keypad Functions
No. (Addr.)
Name
o2-01
LO/RE Key Function Selection
(505H)
o2-02
STOP Key Function Selection
(506H)
o2-03
User Parameter Default Value
(507H)
o2-04
(508H)
Drive Model Selection
<1>
o2-05
Speed Reference Setting Method
(509H)
Selection
o2-06
Operation Selection when Digital
(50AH)
Operator is Disconnected
o2-09
Reserved
(50DH)
<1> Parameter setting value is not reset to the default value when the drive is initialized.
o3: Copy Function
No. (Addr.)
Name
o3-01
Copy Function Selection
(515H)
o3-02
Copy Allowed Selection
(516H)
o4: Maintenance Monitor Settings
No. (Addr.)
Name
o4-01
Cumulative Operation Time
(50BH)
Setting
o4-02
Cumulative Operation Time
(50CH)
Selection
o4-03
Cooling Fan Operation Time
(50EH)
Setting
o4-05
Capacitor Maintenance Setting
(51DH)
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Description
V/f
OLV
Sets the ratio of the gear installed for display unit calculations.
Description
All Modes
0: Disabled
1: Enabled. LO/RE key switches between LOCAL and REMOTE operation.
All Modes
0: Disabled. STOP key is disabled in REMOTE operation.
1: Enabled. STOP key is always enabled.
All Modes
0: No change.
1: Set defaults. Saves parameter settings as default values for a User Initialization.
2: Clear all. Clears the default settings that have been saved for a User Initialization.
All Modes
Enter the drive model. Setting required only if installing a new control board.
All Modes
0: ENTER key must be pressed to enter a speed reference.
1: ENTER key is not required. The speed reference can be adjusted using the up and down
arrow keys only.
All Modes
0: The drive continues operating if the digital operator is disconnected.
1: A fault is triggered (oPr) and the motor coasts to stop.
Description
All Modes
0: No action
1: Read parameters from the drive, saving them onto the digital operator.
2: Copy parameters from the digital operator, writing them to the drive.
3: Verify parameter settings on the drive to check if they match the data saved on the operator.
All Modes
0: Read operation prohibited
1: Read operation allowed
Description
All Modes
Sets the value for the cumulative operation time of the drive in units of 10 h.
All Modes
0: Logs power-on time
1: Logs operation time when the drive output is active (output operation time).
All Modes
Sets the value of the fan operation time monitor U4-03 in units of 10 h.
All Modes
Sets the value of the Maintenance Monitor for the capacitors. See U4-05 to check when the
capacitors may need to be replaced.
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
common_
Default:
<5>
TMonly
Min: 0.10
226
Max: 50.00
Setting
Page
common_
Default: 0
TMonly
Min: 0
226
Max: 1
common_
Default: 0
TMonly
Min: 0
226
Max: 1
common_
TMonly
Default: 0
Min: 0
227
Max: 2
Default: Determined by
common_
drive capacity
TMonly
227
Min: –
Max: –
common_
TMonly
Default: 0
Min: 0
227
Max: 1
common_
Default: 0
TMonly
Min: 0
227
Max: 1
Setting
Page
common_
TMonly
Default: 0
Min: 0
228
Max: 3
common_
Default: 0
TMonly
Min: 0
228
Max: 1
Setting
Page
Default: 0 h
common_
TMonly
Min: 0 h
228
Max: 9999 h
common_
Default: 0
TMonly
Min: 0
228
Max: 1
common_
Default: 0 h
TMonly
Min: 0 h
229
Max: 9999 h
common_
Default: 0%
TMonly
Min: 0%
229
Max: 150%
B
365

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents