YASKAWA L1000A Technical Manual page 355

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

H2-
Function
Setting
12
Timer Output
13
Speed Agree 2
14
User-set Speed Agree 2
15
Speed Detection 3
16
Speed Detection 4
18
Torque Detection 2
1A
During Down Direction
1B
During Baseblock 2 (N.C.)
1C
Motor 2 Selection
1D
During Regeneration
1E
Reset Enabled
1F
Motor Overload Alarm (oL1)
20
Drive Overheat Pre-alarm (oH)
2F
Maintenance Period
30
During Torque Limit
33
Within Position Lock Bandwidth
37
During Frequency Output
50
Brake Control
51
Output Contactor Control
52
Door Zone Reached
53
Not Zero Speed
54
Light Load Direction
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
H2 Multi-Function Digital Output Settings
All Modes
Closed: Timer output.
All Modes
Closed: When drive output frequency equals the speed reference ±L4-04.
All Modes
Closed: When the drive output speed is equal to the value in L4-03 ±L4-04.
All Modes
Closed: When the drive output speed is less than or equal to the value in L4-03 ±L4-04.
All Modes
Closed: When the output speed is greater than or equal to the value in L4-03 ±L4-04.
All Modes
Closed: Overtorque or undertorque has been detected.
All Modes
Closed: Drive is running in the down direction.
All Modes
Open: Drive has entered the baseblock state (no output voltage).
V/f
OLV
Open: Motor 1 is selected
Closed: Motor 2 is selected
V/f
OLV
Closed: Motor is operated in regenerative mode.
All Modes
Closed: An automatic reset is performed
All Modes
Closed: oL1 is at 90% of its trip point or greater. An oH3 situation also triggers this alarm.
All Modes
Closed: Heatsink temperature exceeds the parameter L8-02 value.
All Modes
Closed: Cooling fan, electrolytic capacitors, IGBTs, or the soft charge bypass relay may require maintenance.
V/f
OLV
Closed: When the torque limit has been reached.
V/f
OLV
Closed: Position deviation is within the Position Lock Bandwidth.
All Modes
Open: Either the drive has stopped or baseblock, DC Injection Braking, or Initial Excitation is being performed.
Closed: Drive is running the motor (not in a baseblock state and DC Injection is not being performed).
All Modes
Close: Release brake
Open: Apply brake
All Modes
Closed: Close output contactor
All Modes
Closed: Indicates that the door zone has been reached.
All Modes
Closed: Speed is greater than the zero speed level set to S1-01
Open: Operating at zero speed level
All Modes
Closed: Light load direction is up
Open: Light load direction is down
Description
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
B.3 Parameter Table
Page
common_
TMonly
192
common_
TMonly
192
common_
TMonly
193
common_
TMonly
193
common_
TMonly
193
common_
TMonly
192
common_
TMonly
194
common_
TMonly
194
common_
TMonly
194
common_
TMonly
194
common_
TMonly
194
common_
TMonly
195
common_
TMonly
195
common_
TMonly
195
common_
TMonly
195
common_
TMonly
195
common_
TMonly
195
common_
TMonly
195
common_
TMonly
195
common_
TMonly
196
common_
TMonly
196
common_
TMonly
196
B
355