5.10 o: Operator Related Settings
o4-12: kWh Monitor Initialization
Resets the kWh monitors U4-10 and U4-11. Initializing the drive or cycling the power does not reset these monitors.
No.
o4-12
Setting 0: No Action
The kWh data are kept
Setting 1: Reset kWh Data
Resets the kWh counter. The monitors U4-10 and U4-11 will display "0" after they are initialized. Once o4-12 is set to 1
and the ENTER key is pressed, kWh data is erased and the display returns to 0.
o4-13: Number of Travels Counter Reset
The number of travels counter displayed in U4-24/25 is not reset when the power is cycled or the drive is initialized. Use
o4-13 to reset U4-24/25.
No.
o4-13
Setting 0: No Action
Keeps the number of travels counter.
Setting 1: Resets the Number of Travels
Resets the number of travels counter. The monitor U4-24/25 will show 0. Once o4-13 is set to 1 and the ENTER key is
pressed, the counter value is erased and the display returns to 0.
o4-15: Maintenance Alarm Snooze Period
After a maintenance alarm output has been triggered, o4-15 determines the level that will trigger the next alarm for the
same component. The same alarm will be triggered by the detection level that triggered the original alarm plus the level
set in o4-15.
No.
o4-15
<1> Parameter setting value is not reset to the default value during drive initialization (A1-03).
o4-16: Maintenance Monitoring Selection
Selects the Maintenance Monitor by using bits 0 to 3.
No.
o4-16
<1> Parameter setting value is not reset to the default value during drive initialization (A1-03).
All bits = 0: Maintenance Monitors are disabled
bit 0: LT1 (cooling fan)
bit 1: LT2 (DC bus capacitors)
bit 2: LT3 (soft-charge bypass relay)
bit 3: LT4 (IGBTs have passed 90% of the their life expectancy)
230
Name
kWh Monitor Initialization
Name
Number of Travels Counter Reset
Name
Maintenance Alarm Setting
Name
Maintenance Monitoring Selection
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Setting Range
0 or 1
Setting Range
0 or 1
Setting Range
0 to 20%
Setting Range
0000 to 1111
Default
0
Default
0
Default
2%
<1>
Default
1000