YASKAWA L1000A Technical Manual page 353

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

H1-
Function
Setting
18
Timer Function Input
1A
Accel/decel Ramp Selection 2
20 to 2F
External Fault
50
Nominal Speed
51
Intermediate Speed
52
Releveling Speed
53
Leveling Speed
54
Inspection Operation
55
Rescue Operation
56
Motor Contactor Feedback
57
High Speed Limit (Up)
58
High Speed Limit (Down)
5C
Floor Sensor
67
Communications Test Mode
79
Brake Feedback
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
H1 Multi-Function Digital Input Settings
All Modes
Triggers the timer set up by parameters b4-01 and b4-02. Must be set in conjunction with the timer function output
(H2-
= 12).
All Modes
Used in conjunction with an input terminal set for "Accel/decel ramp selection 1" (H1-
drive to switch between accel/decel ramp 3 and 4.
All Modes
20: N.O., Always detected, ramp to stop
21: N.C., Always detected, ramp to stop
22: N.O., During run, ramp to stop
23: N.C., During run, ramp to stop
24: N.O., Always detected, coast to stop
25: N.C., Always detected, coast to stop
26: N.O., During run, coast to stop
27: N.C., During run, coast to stop
28: N.O., Always detected, Fast Stop
29: N.C., Always detected, Fast Stop
2A: N.O., During run, Fast Stop
2B: N.C., During run, Fast Stop
2C: N.O., Always detected, alarm only (continue running)
2D: N.C., Always detected, alarm only (continue running)
2E: N.O., During run, alarm only (continue running)
2F: N.C., During run, alarm only (continue running)
All Modes
Closed: Activates the nominal speed (d1-19).
All Modes
Closed: Activates the Intermediate Speed (d1-20).
All Modes
Closed: Activates the Releveling Speed (d1-23).
All Modes
Closed: Activates the Leveling Speed (d1-26).
All Modes
Closed: Activates Inspection operation using the speed set in d1-24.
All Modes
Closed: Activates rescue operation.
All Modes
Used for motor contactor supervision and fault detection.
All Modes
Closed: Uses the leveling speed as the maximum speed when going up.
All Modes
Closed: Uses the leveling speed as the maximum speed when going down.
V/f
OLV
Closed: Initiate Direct Landing (S5-10 = 1)
All Modes
Tests the MEMOBUS/Modbus RS-485/422 interface. Displays "PASS" if the test completes successfully.
All Modes
Used for brake supervision and detection of incorrect operation.
Description
CLV
CLV/PM
B.3 Parameter Table
Page
common_
TMonly
186
common_
TMonly
186
= 7), and allows the
common_
TMonly
186
common_
TMonly
187
common_
TMonly
187
common_
TMonly
187
common_
TMonly
187
common_
TMonly
187
common_
TMonly
187
common_
TMonly
187
common_
TMonly
187
common_
TMonly
188
common_
TMonly
188
common_
TMonly
188
common_
TMonly
188
353
B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents