YASKAWA L1000A Technical Manual page 350

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

B.3 Parameter Table
No.(Addr.)
Name
F3-03
DI-A3 Option Card Data Length
(3B9H)
Selection
F4: Analog Monitor Card (AO-A3)
No.(Addr.)
Name
F4-01
Terminal V1 Function Selection
(391H)
F4-02
(392H)
Terminal V1 Gain
F4-03
Terminal V2 Function Selection
(393H)
F4-04
(394H)
Terminal V2 Gain
F4-05
(395H)
Terminal V1 Bias
F4-06
(396H)
Terminal V2 Bias
F4-07
Terminal V1 Signal Level
(397H)
Selection
F4-08
Terminal V2 Signal Level
(398H)
Selection
F5: Digital Output Card (DO-A3)
No.(Addr.)
Name
F5-01
Terminal P1-PC Output Selection
(399H)
F5-02
Terminal P2-PC Output Selection
(39AH)
F5-03
Terminal P3-PC Output Selection
(39BH)
F5-04
Terminal P4-PC Output Selection
(39CH)
F5-05
Terminal P5-PC Output Selection
(39DH)
F5-06
Terminal P6-PC Output Selection
(39EH)
F5-07
Terminal M1-M2 Output Selection
(39FH)
F5-08
Terminal M3-M4 Output Selection
(3A0H)
F5-09
DO-A3 Output Mode Selection
(3A1H)
350
All Modes
0: 8 bit
1: 12 bit
2: 16 bit
All Modes
Sets the monitor signal for output from terminal V1. Set this parameter to the last three digits of
the desired U -
monitor. Some U parameters are available only in certain control modes.
All Modes
Sets the gain for voltage output via terminal V1.
All Modes
Sets the monitor signal for output from terminal V2. Set this parameter to the last three digits of
the desired U -
monitor. Some U parameters are available only in certain control modes.
All Modes
Sets the gain for voltage output via terminal V2.
All Modes
Sets the amount of bias added to the voltage output via terminal V1.
All Modes
Sets the amount of bias added to the voltage output via terminal V2.
All Modes
0: 0 to 10 V
1: -10 to 10 V
All Modes
Sets the function for contact output terminals M1-M2, M3-M4, and photocoupler output
terminals P1 through P6.
All Modes
0: Output terminals are each assigned separate output functions.
1: Binary code output
2: Use output terminal functions selected by parameters F5-01 through F5-08.
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Description
Description
Description
Setting
Page
common_
TMonly
Default: 2
Min: 0
Max: 2
Setting
Page
common_
Default: 102
TMonly
Min: 000
Max: 999
Default: 100.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
common_
Default: 103
TMonly
Min: 000
Max: 999
Default: 50.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
common_
Default: 0.0%
TMonly
Min: -999.9%
Max: 999.9%
Default: 0.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
Default: 1
Min: 0
common_
TMonly
Max: 1
Default: 1
Min: 0
Max: 1
Setting
Page
Default: 0
Min: 0
Max: 161
Default: 1
Min: 0
Max: 161
Default: 2
Min: 0
Max: 161
Default: 4
Min: 0
common_
TMonly
Max: 161
Default: 6
Min: 0
Max: 161
Default: 37
Min: 0
Max: 161
Default: F
Min: 0
Max: 161
Default: F
Min: 0
Max: 161
common_
TMonly
Default: 0
Min: 0
Max: 2
180
180
180
180
180
180
180
181
181
181
181
181
181
181
181
181
181
182

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents