8.2 Drive Options and Peripheral Devices
Option
Remote Operator Cable
USB Copy Unit
Installation Support Set A
Installation Support Set B
24 V Power Supply
DriveWizard Plus
Complementary Signal Encoder
Line Driver Encoder
EnDat Encoder
ERN1387 Encoder
Analog Monitor
Digital Input
Digital Output
CANopen
314
Model Number
Interface Options
WV001/WV003
JVOP-181
Attachment
EZZ020642A
EZZ020642B
Others
PS-A10L, PS-A10H
Communication Options
PG-B3
PG-X3
PG-F3
PG-E3
AO-A3
DI-A3
DO-A3
SI-S3
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Description
Extension cable (1 m or 3 m) to connect the digital operator for
remote operation
RJ-45, 8 pin straight through, UTP CAT5e cable
Allows the user to copy and verify parameter settings between
drives. Can also be used as an adapter to connect the drive to
the USB port on a PC.
For installing the digital operator keypad on the outside of an
enclosure panel that houses the drive. Uses screws to secure the
operator.
For installing the digital operator keypad on the outside of an
enclosure panel that houses the drive.
Uses nuts to secure the operator for installations where screws
are not practical.
Provides power to the control circuit and option boards in the
event of power loss. Allows the user to monitor drive settings
and fault information when the main circuit has no power.
PC tool for drive setup and parameter management
For speed feedback input by connecting a motor encoder
Input: 3 track (can be used with one or two tracks), for HTL
encoder connection, 50 kHz max
Output: 3 track, open collector
Encoder power supply: 12 V, max current 200 mA
For speed feedback input by connecting a motor encoder
Input: 3 track (can be used with one or two tracks), line driver,
300 kHz max
Output: 3 track, line driver
Encoder power supply: 5 V or 12 V, max current 200 mA
Encoder type: EnDat 2.1/01, EnDat 2.2/01 (HEIDENHAIN)
Maximum input frequency: 20 kHz
Pulse monitor: Matches RS-422 level
Output voltage: 5 V±5%, 8 V±10%
Maximum output current: 200 mA
Wiring length: 20 m max. for the encoder, 30 m max. for the
pulse monitor
Encoder type: ERN1387 (HEIDENHAIN)
Maximum input frequency: 20 kHz
Pulse monitor: Matches RS-422 level
Output voltage: 5 V±5%
Maximum output current: 200 mA
Wiring length: 20 m max. for the encoder, 10 m max. for the
pulse monitor
Provides extra analog output terminals for monitoring drive
status.
Output channels: 2
Output voltage: -10 to 10 V, 11 bit (signed)
Used to set the speed reference by digital inputs
Input channels: 18 (including SET signal and SIGN signal)
Input signal type: BCD 16 bit (4 digit), 12 bit (3 digit), 8 bit (2
digit)
Input signal: 24 Vdc, 8 mA
Provides extra insulated digital outputs for monitoring drive
status.
Photocoupler relays: 6 (48 V, up to 50 mA)
Contact relays: 2 (250 Vac/up to 1 A, 30 Vdc/up to 1 A)
Connects to a CANopen network