B.3 Parameter Table
H2-
Function
Setting
Light Load Direction Detection
55
Status
56
Cooling Fan Status
57
Input Phase Loss
58
Safe Disable Status
61
Motor Pole Search Status
100 to 161
Function 0 to 61 with Inverse Output
H3: Multi-Function Analog Inputs
No.(Addr.)
Name
H3-01
Terminal A1 Signal Level
(410H)
Selection
H3-02
Terminal A1 Function Selection
(434H)
H3-03
(411H)
Terminal A1 Gain Setting
H3-04
(412H)
Terminal A1 Bias Setting
H3-09
Terminal A2 Signal Level
(417H)
Selection
H3-10
Terminal A2 Function Selection
(418H)
H3-11
(419H)
Terminal A2 Gain Setting
H3-12
(41AH)
Terminal A2 Bias Setting
H3-13
Analog Input Filter Time Constant
(41BH)
H3-16
Offset for Terminal A1
(2F0H)
H3-17
Offset for Terminal A2
(2F1H)
356
H2 Multi-Function Digital Output Settings
All Modes
Closed: Ready for Light Load Direction Search
Open: Light Load Detection in progress
All Modes
Closed: Cooling fan is operating
All Modes
Closed: Input phase loss has occurred
Open: Normal operation (no phase loss detected)
All Modes
Closed: Safe Disable terminals H1-HC and H2-HC are open, drive is in a baseblock state
Open: Safe Disable terminals H1-HC and H2-HC are closed (normal operation)
All Modes
Closed: Motor pole search successful
All Modes
Inverts the output switching of the multi-function output functions.
Sets the last two digits of 1
to reverse the output signal of that specific function.
All Modes
0: 0 to 10 V
1: –10 to 10 V
All Modes
Sets the function of terminal A1.
All Modes
Sets the level of the input value selected in H3-02 when 10 V is input at terminal A1.
All Modes
Sets the level of the input value selected in H3-02 when 0 V is input at terminal A1.
All Modes
0: 0 to 10 V
1: –10 to 10 V
All Modes
Sets the function of terminal A2.
All Modes
Sets the level of the input value selected in H3-10 when 10 V is input at terminal A2.
All Modes
Sets the level of the input value selected in H3-10 when 0 V is input at terminal A2.
All Modes
Sets a primary delay filter time constant for terminals A1 and A2. Used for noise filtering.
All Modes
Applies an offset to analog input A1. Can be used for zero adjustment of the analog input.
All Modes
Applies an offset to analog input A2. Can be used for zero adjustment of the analog input.
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Description
Description
Page
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
common_
TMonly
Setting
Page
common_
Default: 0
TMonly
Min: 0
Max: 1
Default: 0
common_
TMonly
Min: 0
Max: 1F
Default: 100.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
Default: 0.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
common_
Default: 0
TMonly
Min: 0
Max: 0
Default: 0
common_
TMonly
Min: 0
Max: 1F
Default: 100.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
Default: 0.0%
common_
TMonly
Min: -999.9%
Max: 999.9%
common_
Default: 0.03 s
TMonly
Min: 0.00 s
Max: 2.00 s
Default: 0
common_
TMonly
Min: -500
Max: 500
Default: 0
common_
TMonly
Min: -500
Max: 500
196
196
196
196
196
196
197
197
197
197
198
198
198
198
199
199
199