Figure 5.44
S3-21: Dwell 2 End Speed
The Dwell 2 function will end when the drive reaches this speed. A setting of 0.00 will disable the acceleration rate switch
that occurs at the end of Dwell 2.
No.
S3-21
S3-25: DC Injection Gain in Regenerative Operation
In OLV Control, S3-25 sets a gain level for DC Injection at stop (S1-03) for when the regenerative load reaches 100%. At
that time, the current applied during DC Injection at stop is determined as S1-03 × S3-25.
No.
S3-25
S3-26: DC Injection Gain in Motoring Operation
In OLV Control, S3-26 sets a gain level for DC Injection at stop (S1-03) when the motoring load reaches 100%. At that
time, the current applied during DC Injection at stop is determined as S1-03 × S3-26.
No.
S3-26
S3-27: Torque Compensation Value with Load Condition 1
Adjusts the analog signal from a load sensor for torque compensation. Refer to
Start on page 121
for details.
No.
S3-27
S3-28: Torque Compensation Value with Load Condition 2
Adjusts the analog signal from a load sensor for torque compensation. Refer to
Start on page 121
for details.
No.
S3-28
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Run Command
C1-07
S3-21
Figure 5.44 Dwell Speed Reference at Start
Parameter Name
Dwell 2 End Speed
Parameter Name
DC Injection Gain in Regenerative Operation
Parameter Name
DC Injection Gain in Motoring Operation
Parameter Name
Torque Compensation Value with Load Condition 1
Parameter Name
Torque Compensation Value with Load Condition 2
ON
SFS output
C1-01
Motor speed
C2-01
S3-20
Adjusting the Torque Compensation at
Adjusting the Torque Compensation at
5.11 S: Elevator Parameters
Setting Range
Default
0.00 to 100.00%
0.00%
Setting Range
Default
0 to 400%
100%
Setting Range
Default
0 to 400%
Setting Range
Default
-100.0 to 100.0%
-50.0%
Setting Range
Default
-100.0 to 100.0%
50.0%
20%
5
235