EMC Filters
Install the drive with the EMC filters listed below to comply with the EN61800-3/EN12015 requirements.
Note: If the Safe Disable function of the drive is part of the safety concept of a machine or installation and used for a safe stop according
to EN60204-1, stop category 0, use only filters manufactured by Schaffner as listed below. This also applies when using the safe
disable function in one motor contactor installations as described in
Model
CIMR-L
2A0018
FS5972-35-07
2A0025
2A0033
FS5972-60-07
2A0047
2A0060
FS5972-100-35
2A0075
2A0185
FS5972-170-40
2A0115
2A0145
FS5972-250-37
2A0180
2A0215
FS5972-410-99
2A0283
2A0346
FS5972-600-99
2A0415
4A0009
FS5972-18-07
4A0015
4A0018
FS5972-35-07
4A0024
4A0031
4A0039
FS5972-60-07
4A0045
4A0060
FS5972-100-35
4A0075
4A0091
4A0112
FS5972-170-35
4A0150
4A0180
FS5972-250-37
4A0216
FS5972-410-99
4A0260
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Table D.2 EN61800-3 Filters
Type
Rated Current (A)
Three-Phase 200 V Class
35
60
100
170
250
410
600
Three-Phase 400 V Class
18
35
60
100
170
250
400
Safe Disable Input Function on page
Filter Data (Manufacturer: Schaffner)
Dimensions
Weight
[W x D x H]
(kg)
206 × 50 × 355
2.1
236 × 65 × 408
4.0
90 × 150 × 330
3.4
120 × 170 × 451
6.0
130 × 240 × 610
11.7
260 × 115 × 386
10.5
260 × 135 × 386
11
141 × 46 × 330
1.7
206 × 50 × 355
2.1
236 × 65 × 408
4
90 × 150 × 330
3.4
120 × 170 × 451
4.7
130 × 240 × 610
11.7
260 × 115× 386
10.5
D.2 European Standards
427.
Y x X
(mm)
175 × 336
205 × 390
65 × 255
102 × 365
90 × 498
235 × 120
235 × 120
115 × 313
175 × 336
202 × 390
65 × 255
102 × 365
90 × 498
235 × 120
Figure
1
2
3
1
2
3
D