YASKAWA L1000A Technical Manual page 363

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

No. (Addr.)
Name
n5-03
Inertia Compensation Gain
(5B2H)
n5-07
Speed Feedback Compensation
(170H)
Selection
n5-08
Speed Feedback Compensation
(171H)
Gain (P)
<4> Default setting value is dependent on the drive model (o2-04).
n6: Online Tuning
No. (Addr.)
Name
n6-01
Online Tuning Selection
(570H)
n6-05
Online Tuning Gain
(5C7H)
n8: PM Motor Control Tuning
No. (Addr.)
Name
n8-01
Initial Polarity Estimation Current
(540H)
n8-02
Pole Attraction Current
(541H)
n8-29
q-Axis Current Control Gain
(55CH)
during Normal Operation
n8-30
q-Axis Current Control Integral
(55DH)
Time during Normal Operation
n8-32
d-Axis Current Control Gain
(55FH)
during Normal Operation
n8-33
d-Axis Current Control Integral
(560H)
Time during Normal Operation
n8-35
Initial Rotor Position Detection
(562H)
Selection
n8-36
High Frequency Injection Level
(563H)
n8-37
High Frequency Injection
(564H)
Amplitude
n8-62
Output Voltage Limit
(57DH)
n8-81
High Frequency Injection during
(2D0H)
Rescue Operation
High Frequency Injection
n8-82
Amplitude during Rescue
(2D1H)
Operation
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Description
V/f
OLV
Sets the ratio between motor and load inertia. Lower this setting if overshoot occurs at the end
of acceleration.
V/f
OLV
0: Disabled
1: Enabled
2: Test Mode
V/f
OLV
Sets the proportional gain for the Speed Feedback Compensation.
Description
V/f
OLV
0: Disabled
1: Line-to-line resistance tuning
2: Voltage correction.
V/f
OLV
Decrease this setting for motors with a relatively large rotor time constant.
If overload occurs, increase this setting slowly in increments of 0.1.
Description
V/f
OLV
Sets the current used for initial rotor position estimation as a percentage of the motor rated
current (E5-03). If the motor nameplate lists an "Si" value, that value should be entered here.
V/f
OLV
Sets the current during initial polar attraction as a percentage of the motor rated current. Enter a
high value when attempting to increase starting torque.
V/f
OLV
Sets the q axis proportional gain for the normal control range.
V/f
OLV
Sets the q axis integral time for the normal control range.
V/f
OLV
Sets the d axis proportional gain for the normal control range.
V/f
OLV
Sets the d axis integral time for the normal control range.
V/f
OLV
1: High frequency injection
2: Pulse injection
V/f
OLV
Sets the frequency in Hz for the superimposed signal used for superimposed harmonics.
V/f
OLV
Sets the amplitude for superimposed harmonics according to the voltage class of the motor.
Adjust this value when there is too much or too little current as a result of the settings assigned
to motor parameters.
V/f
OLV
Prevents output voltage saturation. Should be set just below the voltage provided by the input
power supply.
V/f
OLV
Sets the frequency used for Polar Detection Method 1 during Rescue Operation.
V/f
OLV
Sets the amplitude for High Frequency Injection during Rescue Operation as a percentage of the
voltage (200 V or 400 V).
CLV
CLV/PM
CLV/PM
CLV
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
common_
Default: 1.00
TMonly
Min: 0.00
219
Max: 100.00
common_
TMonly
Default: 1
Min: 0
220
Max: 2
common_
Default: 12.00
TMonly
Min: 0.00
220
Max: 300.00
Setting
Page
common_
TMonly
Default: 2
Min: 0
220
Max: 2
common_
Default: 1.0
TMonly
Min: 0.1
220
Max: 50.0
Setting
Page
common_
Default: 50%
TMonly
Min: 0%
221
Max: 100%
common_
Default: 80%
TMonly
Min: 0%
221
Max: 150%
common_
Default: 1000 rad/s
TMonly
Min: 0 rad/s
222
Max: 2000 rad/s
common_
Default: 10.0 ms
TMonly
Min: 0.0 ms
223
Max: 100.0 ms
common_
Default: 1000 rad/s
TMonly
Min: 0 rad/s
223
Max: 2000 rad/s
common_
Default: 10.0 ms
TMonly
Min: 0.0 ms
223
Max: 100.0 ms
common_
Default: 1
TMonly
Min: 1
221
Max: 2
common_
Default: 500 Hz
TMonly
Min: 25 Hz
221
Max: 1000 Hz
common_
TMonly
Default: 20.0%
Min: 0.0%
222
Max: 99.9%
common_
Default: 200.0 V
<9>
TMonly
Min: 0.0 V
223
Max: 230.0 V
<9>
common_
Default: 90 Hz
TMonly
Min: 25 Hz
222
Max: 1000 Hz
common_
Default: 15.0%
TMonly
Min: 0.1%
222
Max: 99.9%
B
363

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents