YASKAWA L1000A Technical Manual page 360

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

B.3 Parameter Table
L5: Automatic Fault Reset
No. (Addr.)
Name
L5-01
Number of Auto Reset Attempts
(49EH)
L5-02
Fault Output Operation during
(49FH)
Auto Reset
L5-04
Fault Reset Interval Time
(46CH)
L5-06
Undervoltage Fault Reset
(522H)
Selection
L6: Torque Detection
No. (Addr.)
Name
L6-01
Torque Detection Selection 1
(4A1H)
L6-02
Torque Detection Level 1
(4A2H)
L6-03
Torque Detection Time 1
(4A3H)
L6-04
Torque Detection Selection 2
(4A4H)
L6-05
Torque Detection Level 2
(4A5H)
L6-06
Torque Detection Time 2
(4A6H)
360
All Modes
Sets the number of times the drive may attempt to reset after the following faults occur: GF, LF,
oC, ov, rr, oH1, oL1, oL2, oL3, oL4, UL3, UL4.
All Modes
0: Fault output not active.
1: Fault output active during reset attempt.
All Modes
Sets the amount of time to wait between performing fault reset.
All Modes
0: Same as L5-01 condition
1: Always automatically reset UV1
All Modes
0: Disabled
1: oL3 detection only active during speed agree, operation continues after detection
2: oL3 detection always active during run, operation continues after detection
3: oL3 detection only active during speed agree, output shuts down on an oL3 fault
4: oL3 detection always active during run, output shuts down on an oL3 fault
5: UL3 detection only active during speed agree, operation continues after detection
6: UL3 detection always active during run, operation continues after detection
7: UL3 detection only active during speed agree, output shuts down on an oL3 fault
8: UL3 detection always active during run, output shuts down on an oL3 fault
All Modes
Sets the overtorque and undertorque detection level.
All Modes
Sets the time an overtorque or undertorque condition must exist to trigger torque detection 1.
All Modes
0: Disabled
1: oL4 detection only active during speed agree, operation continues after detection
2: oL4 detection always active during run, operation continues after detection
3: oL4 detection only active during speed agree, output shuts down on an oL4 fault
4: oL4 detection always active during run, output shuts down on an oL4 fault
5: UL4 detection only active during speed agree, operation continues after detection
6: UL4 detection always active during run, operation continues after detection
7: UL4 detection only active during speed agree, output shuts down on an oL4 fault
8: UL4 detection always active during run, output shuts down on an oL4 fault
All Modes
Sets the overtorque and undertorque detection level.
All Modes
Sets the time an overtorque or undertorque condition must exist to trigger torque detection 2.
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Description
Description
Setting
Page
common_
Default: 0
TMonly
Min: 0
Max: 10
common_
Default: 0
TMonly
Min: 0
Max: 1
Default: 10.0 s
common_
TMonly
Min: 0.5 s
Max: 600.0 s
common_
Default: 0
TMonly
Min: 0
Max: 1
Setting
Page
common_
TMonly
Default: 0
Min: 0
Max: 8
Default: 150%
common_
TMonly
Min: 0%
Max: 300%
Default: 0.1 s
common_
TMonly
Min: 0.0 s
Max: 10.0 s
common_
TMonly
Default: 0
Min: 0
Max: 8
Default: 150%
common_
TMonly
Min: 0%
Max: 300%
common_
Default: 0.1 s
TMonly
Min: 0.0 s
Max: 10.0 s
208
208
209
209
210
210
210
210
210
210