5.11 S: Elevator Parameters
Run Command
(Forward [Up] / Reverse [Down])
H2-
= 53 (Not Zero
Speed)
H2-
= 51
(Output Contactor
H1-
= 56
(Motor Contactor
Feedback)
H2-
= 50 (Brake
Control)
Operation
Speed
<1> Area S is the stopping distance (S5-12) from the point at which leveling operation is complete to when the car arrives at the designated
floor.
S5-10: Stopping Method Selection
Selects the stopping method.
No.
S5-10
0: Disable
1: Direct Landing
2: Leveling Distance Control
S5-11: Deceleration Distance
Sets the deceleration distance when Stop Distance Control is enabled.
No.
S5-11
<1> The setting range becomes 0.00 to 650.00 inches when the length units are set for inches (o1-12 = 1).
S5-12: Stop Distance
Sets the stopping distance when Stop Distance Control is enabled. Refer to
Distance Control on page 243
No.
S5-12
<1> The setting range becomes 0.00 to 393.00 inches when the length units are set for inches (o1-12 = 1).
244
Control)
Run Command Delay Time (S1-10)
Brake Release Delay Time
(S1-06)
Zero Speed
at Start
Figure 5.47 Operation Sequence Example for Leveling Distance Control
Parameter Name
Stopping Method Selection
Parameter Name
Deceleration Distance
for details.
Parameter Name
Stop Distance
ON
OFF
ON
ON
ON
ON
Refer to Direct Landing on page 242
Direct Landing on page 242
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
OFF
OFF
Output Contactor Open
Delay Time (S1-11)
OFF
Brake Apply
Delay Time
(S1-07)
Zero Speed
at Stop
S
<1>
Setting Range
0 to 2
Setting Range
0 to 32767 mm
<1>
and
Setting Range
0 to 10000 mm
<1>
Time
Default
0
for details.
Default
0 mm
Leveling
Default
0 mm