YASKAWA L1000A Technical Manual page 349

Ac drive for elevator applications; type: cimr-luxa; 200 v class: 3.7 to 110 kw (5 to 150 hp); 400 v class: 3.7 to 132 kw (5 to 200 hp) a
Hide thumbs Also See for L1000A:
Table of Contents

Advertisement

No.(Addr.)
Name
F1-04
Operation Selection at Deviation
(383H)
F1-05
Encoder 1 Rotation Direction
(384H)
Selection
F1-06
PG 1 Pulse Monitor Output
(385H)
Division Ratio
F1-08
Overspeed Detection Level
(387H)
F1-09
Overspeed Detection Delay Time
(388H)
F1-10
Excessive Speed Deviation
(389H)
Detection Level
F1-11
Excessive Speed Deviation
(38AH)
Detection Delay Time
F1-14
PG Open-Circuit Detection Time
(38DH)
F1-18
dv3 Detection Selection
(3ADH)
F1-19
dv4 Detection Selection
(3AEH)
F1-20
PG Option Card Disconnect
(3B4H)
Detection 1
F1-29
dEv Detection Condition Selection
(3BFH)
F1-51
PGoH Detection Level
(3D3H)
F1-63
PG-E3 R Track Selection
(2DFH)
<5> Default setting is determined by the control mode (A1-02).
<34> Setting range is 1 to 15000 ppr when the drive is set for CLV/PM.
F3: Digital Input Card (DI-A3)
No.(Addr.)
Name
F3-01
DI-A3 Option Card Input Selection
(390H)
YASKAWA ELECTRIC SIEP C710616 38A YASKAWA AC Drive L1000A Technical Manual
Description
V/f
OLV
0: Ramp to stop. Decelerate to stop using the deceleration ramp in C1-02.
1: Coast to stop.
2: Fast Stop. Decelerate to stop using the deceleration ramp in C1-09.
3: Alarm only.
V/f
OLV
0: A phase leads B in up direction
1: B phase leads A in up direction
V/f
OLV
Sets the division ratio for the pulse monitor used of the PG option card installed to connector
CN5-C. By setting "xyz", the division ratio becomes = [(1 + x) / yz]. If only using the A pulse
for one track input, then the input ratio will be 1:1, regardless of what F1-06 is set to.
V/f
OLV
Sets the overspeed detection level as a percentage of the maximum output frequency.
V/f
OLV
Sets the time in seconds for an overspeed situation to trigger a fault (oS).
V/f
OLV
Sets the speed deviation detection level as a percentage of the maximum output frequency.
V/f
OLV
Sets the time in seconds for a speed deviation situation to trigger a fault (dEv).
V/f
OLV
Sets the time required to trigger a PG Open fault (PGo).
V/f
OLV
0: Disabled
n: Sets the number of dv3 situations that may be detected before triggering an actual dv3 fault.
V/f
OLV
0: Disabled
n: Number of pulses that the A and B pulse are reversed that triggers dv4 detection.
V/f
OLV
0: Disabled
1: Enabled
V/f
OLV
Selects when DEV is active.
0: After speed reference, soft starter output and motor speed have matched once.
1: After speed reference and soft starter output have matched once.
2: Always during Run
V/f
OLV
Sets the level for detecting PG Hardware Fault (PGoH). Available when F1-20 = 1
V/f
OLV
0: Disabled
1: Enabled
Description
All Modes
0: BCD, 1% units
1: BCD, 0.1% units
2: BCD, 0.01% units
3: BCD, 1 Hz units
4: BCD, 0.1 Hz units
5: BCD, 0.01 Hz units
6: BCD customized setting (5 digit), 0.02 Hz units
7: Binary input
When the digital operator units are set to be displayed in Hertz or user-set units (o1-03 = 2 or 3),
the units for F3-01 are determined by parameter o1-03.
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
CLV
CLV/PM
B.3 Parameter Table
Setting
Page
common_
TMonly
Default: 3
Min: 0
177
Max: 3
common_
Default:
<5>
TMonly
Min: 0
178
Max: 1
common_
TMonly
Default: 1
Min: 1
178
Max: 132
common_
Default: 115%
TMonly
Min: 0%
177
Max: 120%
common_
Default: 0.0 s
TMonly
Min: 0.0 s
177
Max: 2.0 s
common_
Default: 10%
TMonly
Min: 0%
177
Max: 50%
common_
Default: 0.5 s
TMonly
Min: 0.0 s
177
Max: 10.0 s
common_
Default: 2.0 s
TMonly
Min: 0.0 s
177
Max: 10.0 s
common_
Default: 10
TMonly
Min: 0
178
Max: 10
common_
Default: 128
TMonly
Min: 0
178
Max: 5000
common_
Default: 1
TMonly
Min: 0
179
Max: 1
common_
TMonly
Default: 2
Min: 0
179
Max: 2
common_
Default: 80%
TMonly
Min: 1%
179
Max: 100%
common_
Default: 0
TMonly
Min: 0
179
Max: 1
Setting
Page
common_
TMonly
Default: 0
Min: 0
180
Max: 7
B
349

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents